Features & Benefits
Specifications
Unit | Width | Length | Units per Case | Cases per Pallet | Units per Pallet |
---|---|---|---|---|---|
Roll | 12 in. | 75 ft. | 3 | 25 | 75 |
Roll | 18 in. | 75 ft. | 2 | 25 | 50 |
Roll | 24 in. | 75 ft. | 2 | 25 | 50 |
Roll | 36 in. | 75 ft. | 1 | 25 | 25 |
<b>DuPont™ DuraGard™ CM</b> exhibits physical properties as indicated when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.
TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
---|---|---|---|
STRENGTH | |||
ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Tensile Strength | > 1300 psi |
WATER | |||
ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | Permeability | <0.01 perms for both wet and dry cup |
ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | Wall Assembly Water Penetration Resistance at 6.27 psf (300 Pa) | PASS |
AIR | |||
ASTM E2357 | Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies | Wall Assembly Air Penetration Resistance | <0.04 cfm/ft2 @ 75 Pa |
ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | Wall Assembly Air Penetration Resistance | <0.04 cfm/ft2 @ 75 Pa |
GENERAL | |||
ASTM D1970 | Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Nail Sealability | PASS |
ASTM E154 | Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover | Puncture Resistance | 115 lbs |
AAMA 711 | Specification for Self-Adhering Flashing Used for Installation of Exterior Wall Fenestration Products | Material Standard for Self-Adhering Flashing Surrounding Exterior Wall Fenestration | Class A (no primer) and Level 3 Thermal Exposure (80°C/176°F for 7 days) |
AAMA 711 | Specification for Self-Adhering Flashing Used for Installation of Exterior Wall Fenestration Products | Fastener Sealability (sec. 5.2) | PASS |
DuPont Product | DuraGard™ Adheres to Product | Adheres to DuraGard™ |
---|---|---|
DuPont™ ArmorWall™ Plus Fire-Rated Structural Insulated Sheathing | Yes | n/a |
DuPont™ ArmorWall™ SP Plus Fire-Rated Structural Insulated Sheathing | Yes | n/a |
LiquidArmor™ QS | Yes | Yes |
LiquidArmor™ LT | Yes (primer required)<sup>1</sup> | Yes |
Thermax™ XARMOR™ (ci) | Yes | n/a |
Thermax™ Sheathing | Yes | n/a |
Tyvek® Fluid Applied WB+™ | Yes (primer required)<sup>1</sup> | Yes |
DuPont™ StraightFlash™ | Yes | Yes (primer required)<sup>1</sup> |
Tyvek® Fluid Applied Flashing & Joint Compound+ | Yes (primer required)<sup>1</sup> | Yes |
Styrofoam™ Brand XPS Insulation | Yes | n/a |
1Consult DuPont for approved primers