Features & Benefits
Specifications
| Unit | Width | Length |
|---|---|---|
| Roll | 36 in. | 67 ft. |
<b>Tyvek® Protec PSU</b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact your local DuPont™ Tyvek Specialist before writing specifications around this product. Product properties are as follows:
| TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
|---|---|---|---|
| STRENGTH | |||
| ASTM D1970 | Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Tensile strength (MD / CD) | MD: 100 lbs CD: 90 lbs |
| ASTM D1970 | Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Plywood Adhesion | 36 lbs/ft |
| WATER | |||
| ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | MVTR (Moisture Vapor Transmission Rate) | <0.03 Perms |
| ASTM D4869 | Standard Specification for Asphalt-Saturated Organic Felt Underlayment Used in Steep Slope Roofing | Liquid Water Transmission | Pass |
| GENERAL | |||
| ASTM D1777 | Standard Test Method for Thickness of Textile Materials | Nominal Thickness | 50 mils |