Features & Benefits
Specifications
| Unit | Unit Size | Units per Case | Cases per Pallet | Units per Pallet |
|---|---|---|---|---|
| Cartridge | 28 oz | 12 | 60 | 720 |
| Pail | 3.5 Gallon | - | - | 36 |
<b>Tyvek® Fluid Applied Flashing and Joint Compound+</b> exhibits physical properties as indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.
| TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
|---|---|---|---|
| FIRE | |||
| NFPA 285 | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components | Flame Propagation. Multiple Assemblies | PASS |
| STRENGTH | |||
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Tensile | 245 psi |
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Elongation at Break | 400% |
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Recovery (held at 300% elongation) | >99% |
| ASTM D2240 | Standard Test Method for Rubber Property—Durometer Hardness | Hardness (Shore A) | 69 |
| AIR | |||
| ASTM E2178 | Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials | Air Penetration Resistance | 0.0002 cfm/ft2 @ 75 Pa (1.57 psf) |
| TAPPI T-460 | Air resistance of paper (Gurley method), Test Method | Air Penetration Resistance | >10,000 sec/100 cc |
| ASTM E2357 | Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies | Wall Assembly Air Penetration Resistance | <0.01 cfm/ft2 @ 75 Pa (1.57 psf) |
| ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | Wall Assembly Air Penetration Resistance | <0.01 cfm/ft2 @ 75 Pa (1.57 psf) |
| WATER | |||
| AATCC 127 | Test Method for Water Resistance: Hydrostatic Pressure | Water Penetration Resistance | >1000 cm |
| ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | Wall Assembly Water Penetration Resistance | No leakage Tested to 15 psf |
| ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | Water Vapor Transmission Method B | 25 perm @ 25 mils |
| ADHESION | |||
| ASTM D903 | Standard Test Method for Peel or Stripping Strength of Adhesive Bonds | Peel Strength | 19 lbf/in; cohesive failure (aluminum) |
| ASTM C794 | Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants | Adhesion-In-Peel | PASS (mortar) |
| GENERAL | |||
| ASTM D1970 | Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Nail Sealability | PASS No leakage |
| AAMA 714 | Specification for Liquid Applied Flashing Used to Create a Water-Resistive Seal around Exterior Wall Openings in Buildings | Voluntary Specification for Liquid-Applied Flashing Used to Create a Water Resistive Seal Around Exterior Wall Opening in Buildings. | PASS |
| ASTM C1250 | Standard Test Method for Nonvolatile Content of Cold Liquid-Applied Elastomeric Waterproofing Membranes | VOC | <2 % (by wt.) 25-30 g/L |
| ASTM C1305 | Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane | Low Temperature Crack Bridging | PASS No cracking at 25 mil thickness |
Note:- Test results shown represent averages. Individual results may vary either above or below averages due to normal manufacturing variations, while continuing to meet product specifications.
Learn the essential steps for installing DuPont™ Tyvek® as part of a high‑performance building envelope system. Our installation guides will show how proper installation helps maximize air and water protection for long‑lasting home durability.
Vapor permeability plays a critical role in protecting walls from trapped moisture, mold and rot. Learn how DuPont™ Tyvek® water-resistive barriers provide the ideal balance of air and water resistance with high breathability to help walls dry effectively.
The DuPont Building Envelope Specialist Network delivers hands‑on technical support, training and guidance to help teams build durable, energy‑efficient structures. Discover how DuPont pairs advanced product performance with unmatched field expertise to support your project every step of the way.
DuPont offers a full range of product and system warranties designed to protect builders and property owners with reliable, long‑term coverage. Explore how DuPont™ Tyvek® warranties, along with expert project support, help ensure durable, high‑performing building envelope systems.
Learn how DuPont is advancing sustainable construction with building envelope systems designed to improve energy efficiency, indoor environmental quality, and long‑term durability. Discover how DuPont™ Tyvek® water-resistive barriers help reduce air leakage, protect insulation performance, and support greener, longer‑lasting buildings.