Features & Benefits
Specifications
| Unit | Unit Size |
|---|---|
| Pail | 5 Gallons |
| Drum | 50 Gallons |
<b>Tyvek® Fluid Applied WB+ </b> exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact your local DuPont™ Tyvek Specialist before writing specifications around this product. Product properties are as follows:
| TEST METHOD | TEST TITLE | PROPERTY | RESULTS |
|---|---|---|---|
| AIR | |||
| ASTM E1677 | Standard Specification for Air Barrier (AB) Material or Assemblies for Low-Rise Framed Building Walls | Wall Assembly Air & Water Leakage | Type 1 |
| ASTM E2178 | Standard Test Method for Determining Air Leakage Rate and Calculation of Air Permeance of Building Materials | Air Penetration Resistance | .0002 cfm/ft2@ 75 Pa (1.57 psf) |
| ASTM E2357 | Standard Test Method for Determining Air Leakage Rate of Air Barrier Assemblies | Wall Assembly Air Penetration Resistance | <0.0002 cfm/ft2@ 75 Pa |
| ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | Wall Assembly Air Penetration Resistance | <0.0002 cfm/ft2@ 75 Pa |
| TAPPI T460 | Air resistance of paper (Gurley method) | Air Penetration Resistance | >10,000 sec/100cc |
| ADHESION | |||
| ASTM C794 | Standard Test Method for Adhesion-in-Peel of Elastomeric Joint Sealants | Adhesion - in - Peel | Pass lbf/in. (mortar) |
| ASTM D903 | Standard Test Method for Peel or Stripping Strength of Adhesive Bonds | Peel Strength | 13 Cohesive Failure lbf/in (aluminum) |
| ASTM D4541 | Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers | Adhesion Strength - Exterior Gypsum (delaminates fiber glass top sheet) | >25 psi |
| ASTM D7234 | Standard Test Method for Pull-Off Adhesion Strength of Coatings on Concrete Using Portable Pull-Off Adhesion Testers | Adhesion Strength - Concrete | >33 psi |
| FIRE | |||
| NFPA 285 | Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Wall Assemblies Containing Combustible Components | Flame Propagation. Multiple Assemblies | Pass |
| ASTM E84 | Standard Test Method for Surface Burning Characteristics of Building Materials | Surface Burning Characteristics Class A Index | Flame Spread = 15 Smoke Developed = 10 |
| STRENGTH | |||
| ASTM D412 | Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers—Tension | Tensile Elongation at Break Recovery (held at 300% elongation) | 140 psi 320 % 99 % |
| ASTM D2240 | Standard Test Method for Rubber Property—Durometer Hardness | Hardness | 34 Shore A |
| ASTM D1970 | Standard Specification for Self-Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection | Nail Sealability | Pass No Leakage |
| WATER | |||
| AATCC 127 | Test Method for Water Resistance: Hydrostatic Pressure | Water Penetration Resistance | >1000 cm |
| ASTM E96 | Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials | Water Vapor Transmission | 22 @ 25 mils thick Method B Perms |
| ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | Wall Assembly Water Penetration Resistance | No Leakage Tested to 15 psf |
| ASTM C1250 | Standard Test Method for Nonvolatile Content of Cold Liquid-Applied Elastomeric Waterproofing Membranes | VOC | <2 25-30 % (by wt) g/L |
| GENERAL | |||
| ASTM D2369 | Standard Test Method for Volatile Content of Coatings | Solids | 0.99 |
| ASTM C1305 | Standard Test Method for Crack Bridging Ability of Liquid-Applied Waterproofing Membrane | Low Temperature Crack Bridging | Pass No Cracking at 25 mil Thickness |
| ASTM C679 | Standard Test Method for Tack-Free Time of Elastomeric Sealants | Skin Over Time @ 50% R.H. and 70° F | 1 to 2 hrs |